Skip to content

Smart meter overview

There are different smart meters with corresponding features. The table below shows all known smart meters. It also mentions if you need to connect an external usb power supply (5V-1A) to your gateway.

How do I know if the correct firmware is installed?

When you log in to the gateway you will see the following screen:

Gateway Type shows the active firmware.

If the number of Telegrams with errors is less than Telegrams received then you do not need to do anything. The gateway successfully receives data from the meter.

If Telegrams with errors equals Telegrams received or both numbers remain 0, the gateway’s firmware needs to be changed.

Using the gateway’s firmware menu, install the firmware appropriate for your meter. The tables below show all smart meters with the required firmware. Click on the Frimware menu and choose the required frmware.

The gateway automatically downloads the selected firmware and reboots. Gateway Type shows the firmware installed. If after installing the firmware Telegrams received is greater than Telegrams with errors you know that the correct firmware for your meter has been installed.

Smart Meter Gateway

without display

Smart Meter Gateway

with display

Smart Meter Gateway

without display

Smart Meter Gateway

with display

Netherlands

All smart meters in The Netherlands are compatible with our gateways. If your meter is not listed, please contact us so we can check compatibility for you. When your meter is compatible and not listed we will add it to the list.

Brand:Model:DSMR version:Firmware version:USB power required?
IskraME 382DSMR 2.2Netherlands DSMR2YES
IskraMT 382DSMR 2.2Netherlands DSMR2YES
IskraAM 550ESMR 5.0Netherlands DSMR4+5NO
KaifaE0003DSMR 4Netherlands DSMR4+5YES
KaifaE0025DSMR 4Netherlands DSMR4+5YES
KaifaE0026DSMR 4.2Netherlands DSMR4+5YES
KaifaMA105DSMR 4.0Netherlands DSMR4+5YES
KaifaMA105CDSMR 4.2.2Netherlands DSMR4+5YES
KaifaMA105H2CNLSMR 5Netherlands DSMR4+5NO
KaifaMA304DSMR 4.0Netherlands DSMR4+5NO
KaifaMA304CDSMR 4.2.2Netherlands DSMR4+5YES
KaifaMA304H4CNLSMR 5Netherlands DSMR4+5NO
KaifaMA304 E0079SMR 5.5Netherlands DSMR4+5NO
Kamstrup162DSMR 2.2Netherlands DSMR2YES
Kamstrup351DSMR 2.2Netherlands DSMR2YES
Kamstrup382DSMR 2.2Netherlands DSMR2YES
Landis + GyrE350 (ZCF100)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE350 (ZFF100)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE350 (ZMF100)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE350 (ZCF110CBtFs2)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE350 (ZCF110CBtFs2)SMR 5.0Netherlands DSMR4+5NO
Landis + GyrE360 (ZCF110CCtFs2)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE360 (ZMF110CCtFs2)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE360 (ZMF110CCtFs2)SMR 5.0Netherlands DSMR4+5NO
Landis + GyrE360 (ZMF110CCtFs2)SMR 5.0Netherlands DSMR4+5NO
Landis + GyrE360 (ZMF110CBtFs2)DSMR 4.0Netherlands DSMR4+5YES
Landis + GyrE360 (ZMF110CBtFs2)SMR 5.0Netherlands DSMR4+5NO
Landis + GyrE360 (ZMF120ACtFs2)DSMR 2.2Netherlands DSMR2YES
Landis + GyrE360 (ZMF120ABdFs2)DSMR 2.2Netherlands DSMR2YES
Landis + GyrE360 (CD2D)SMR 5.0Netherlands DSMR4+5NO
Landis + GyrE360 (T11142)SMR 5.0Netherlands DSMR4+5NO
METCOM – High consumption connectionsMCS301SMR 5.0Netherlands DSMR4+5NO
SagemcomT210 / T211ESMR 5.0Netherlands DSMR4+5NO
SagemcomS210 / S211ESMR 5.0Netherlands DSMR4+5NO
SagemcomXS210 ESMR5ESMR 5.0Netherlands DSMR4+5NO
ZIVE0058 1 and 3 phaseESMR 5.0Netherlands DSMR4+5NO
ZIVE0063 1 and 3 phaseESMR 5.0Netherlands DSMR4+5NO
ZIVE0069 1 and 3 phaseESMR 5.0Netherlands DSMR4+5NO
ZIVE0077 1 and 3 phaseESMR 5.0Netherlands DSMR4+5NO

Belgium

All smart meters in Belgum (Fluvius / Sibelga and others) are compatible with our gateways. If your meter is not listed, please contact us so we can check compatibility for you. When your meter is compatible and not listed we will add it to the list.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0BELGIAN*NO

* Port must be activated first: https://www.fluvius.be/nl/thema/meters-en-meterstanden/digitale-meter/maak-je-meter-slim

Sweden

All smart meters in Sweden are tested and working with our gateways. The smart meter has to have a P1 port (6 pole RJ-12 connector) and use the D(SMR) of ESMR standard.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0SWEDEN-DENMARK-FINLANDNO

Denmark

All smart meters in Denmark are tested and working with our gateways.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0SWEDEN-DENMARK-FINLANDNO

Finland

All smart meters in Finland are tested and working with our gateways.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0SWEDEN-DENMARK-FINLANDNO

Hungary

All smart meters in Hungary are tested and working with our gateways.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0HUNGARYNO

Lithuania

All smart meters in Lithuania are tested and working with our gateways.

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0LITHUANIANO

Switzerland

All smart meters in Lithuania are tested and working with our gateways.

Encrypted P1 data is not supported

Brand:Model:DSMR version:Firmware version:USB power required?
All smart metersAll typesSMR 5.0Netherlands DSMR4+5NO